Does a reboot fix it? If so, is it worth using a scheduled script to test it every 10 minutes and reboot the device if it sees it in half-duplex? On 16 October 2015 at 08:44, Paul Julian <paul@oxygennetworks.com.au> wrote:
Hi guys, a while back I asked the list about the issues we seem to have with Omnitik 5Hnd units and them randomly syncing up in half-duplex 10M, I have exhausted all options with these and after just having yet another one do it I am at my wits end.
It doesn't seem to matter whether you use auto-negotiate or try and hard set the interface speed on the device itself or the device that plus into it but they just randomly decide to go to 10M half-duplex, has anybody else seen this and come up with a concrete fix by any chance ? It only happens on Omnitiks and it seems that it's only on the ether1 port from what I can see.
Regards Paul _______________________________________________ Public mailing list Public@talk.mikrotik.com.au http://talk.mikrotik.com.au/mailman/listinfo/public_talk.mikrotik.com.au
-- Damien Gardner Jnr VK2TDG. Dip EE. GradIEAust rendrag@rendrag.net - http://www.rendrag.net/ -- We rode on the winds of the rising storm, We ran to the sounds of thunder. We danced among the lightning bolts, and tore the world asunder